                                    « Frame column stiffness
                                    Multistorey plane frames »
                                 | 
                            
                            
                                
                                    
                                        
                                              
                                        
			Coupled one-storey plane frames  
							As coupled plane frames are defined the plane frames that are connected in such a way that, subject to horizontal forces, they present uniform		displacements.	  				The crossbars of the one-bay frames illustrated in the following figure have a practically infinite moment of inertia. Both columns of the first frame		have moment of inertia Ι whereas the two columns of the second have Ι and 8Ι respectively.	  		 
			
				Figure 5.2-1	Figure 5.2-1  
									In conclusion, 73% of the seismic shear force is carried by the fourth column.	  				Example 5.2					: Consider that the first three columns have a typical cross-section 400/400 and are 5.0 m high and that the fourth one differs only regarding one			of its sides (800 mm instead of 400 mm/400,				Ι		800/400		=8		Ι		400/400		). The seismic acceleration factor is 		a		/		g		=0.10.	  						H		=		4·(0.10·800kN)=		320 		kN	  				Va		=		Vb		=		Vc		=320		·1		/11=29.1 		kN		 		and 		Vd		=320·8/11=232.7 		kN	  				Ma1=-Ma2=Mb1=-Mb2= Mc1=-Mc2=29.1·5.0/2=72.8 kNm 		and		 Md1=-Md2=232.7·3.0/2=349.1 kNm	  				Ka=Kb=Kc=		12		·		EI		/		h		3		=12		·		32.8		·		109		·		Ν		/m2		·		21.33		·		10-4m4/(5.03		·		m3)=6.72·106 		N		/		m			  						Kd=12E		·		8I/h3=8·		6.72·106N/m		=53.74		·		106 N/m	  				Σ		(K)=11·		6.72·106=		73.89		·		106 N/m	 				Therefore,	 				δ		=		H		/		Σ		(K)=320·103N/(73.89		·		106 N/m) =4.331 		mm	 	 				In project <B_520> of the related software, the cross-section of columns C1, C2 and C3 is 400/400 and C4 is 800/400. The height of all columns is		5.0 m. The cross-section of the flanged beam is 250/500/1010/150 and its span is 5.0 m.	  				 
			
				Figure 5.2-2: The structural frame model fully stiffened, project <B_520>	Figure 5.2-2: The structural frame model fully stiffened, project <B_520>  
			 																	 
			
				Figure 5.2-3: Elastic line, δ=8.078mm	Figure 5.2-3: Elastic line, δ=8.078mm  
			 | 			 																				 
			
				Figure 5.2-4: Shear force diagrams	Figure 5.2-4: Shear force diagrams  
			 | 			 																													 
			
				Figure 5.2-5: Bending moment diagrams	Figure 5.2-5: Bending moment diagrams  
			 | 			 					  				It should be noted that the actual displacement of the crossbar δ=8.078 mm is almost twice the value of the corresponding theoretical		value δ=4.331 mm assuming fixed end conditions. This is mainly due to the strong column and the normal beam, which results		in a significantly smaller actual stiffness.	  				The actual stiffness of columns C1, C2	  				Ka=Kb=Va/		δ		=44.5·103N/0.008078=5.51·106 kN/m	  				as well as the actual stiffness of column C3	  				Kc=Vc/		δ		=52.0·103N/0.008078m=6.44·106 kN/m	  				differ slightly from the corresponding value (6.72·106 N/m) of the fixed-ended column.	  				On the contrary, the actual stiffness of column C4	  				Kd=Vd/		δ		=179.0·103N/0.008078m=22.16·106 kN/m	  				differs significantly from the corresponding value (53.74·106 N/m) of the fixed-ended column.	  
			
			
                                    
                                    
                                 | 
                            
                            
                                
                                     
                                    « Frame column stiffness